Calvora

Technology

How we make it.

Process discipline borrowed from precision manufacturing. Applied to dentistry.

Milling

Our mills. Every spec published.

01

MEK T8 Pro

5-axis wet mill: our primary milling machine

The T8 Pro is our primary milling centre: a 5-axis wet mill with a 32-tool automatic changer. It handles everything from single crowns to multi-unit implant bridges without manual intervention between jobs.

MEK T8 Pro technical specifications
ParameterValue
Axes5 (A-axis: 360°)
Tool changer32 tools automatic
Spindle speed40,000 – 60,000 rpm
Spindle power4 kW
Machine power7.5 kW
FixtureSquare disc 140×150mm / Round disc 98mm
Milling modeWet milling (water cooling)
Machine dimensions860 × 741 × 1,763 mm
Weight550 kg
Input voltage220V
Milling materialsZirconia, multilayer zirconia, PMMA, PEEK, HPP, titanium crowns, premill abutments, implant bridges, removable dentures
02

MEK X5

Dry mill: zirconia station

The X5 handles dry milling of pre-sintered zirconia blocks — the first stage of zirconia fabrication before the sintering furnace. Running zirconia here keeps the T8 Pro free for wet milling, so both mills work through the night.

MEK X5 technical specifications
ParameterValue
Axes4 (A-axis: ±25°)
Tool changer3 tools
Spindle speed3,000 – 51,000 rpm
Spindle power1.2 kW
Machine power1.2 kW
Milling modeDry milling
CoolingWater cooling (CW-3000TG chiller)
Machine dimensions610 × 565 × 720 mm
Weight93 kg
Input voltage220V

The T8 Pro and X5 run in parallel, so wet and dry milling happen at the same time without scheduling conflicts.

Equipment

Furnaces, CAD and printing.

Zirconia sintering furnace

In-house, overnight sintering programme

Ivoclar Programat

Ceramic firing for porcelain

exocad

Industry-standard CAD — every design reviewed before milling

3D printing

Surgical guides, working models, printed provisionals

Quality system

Checked before it leaves the lab.

Every unit is checked for fit, contacts, occlusion, shade and finish before it is dispatched, and every status change in the portal is logged with a timestamp and a name.

  1. 01Marginal fit
  2. 02Internal seating
  3. 03Proximal contacts
  4. 04Occlusion
  5. 05Shade
  6. 06Surface finish
  7. 07Anatomy
  8. 08Implant fit
  9. 09Sintering integrity
  10. 10Prescription match
  11. 11Packaging

Digital intake

Send it any way you work.

File formats
STL, PLY, DCM, OBJ
Physical
Impressions collected by our team
Every case gets
A case number, a timeline, and a dispatch notification

Send your first case tonight.
Judge us by the crown.

Open a lab account